Fire-Rated Glass for Education Facilities

IBC / NFPA 101 / AS 1530.4 / BS 476 fire-rated glazing for K-12 schools, universities, and campus buildings. EI30 to EI120, with combined security glass options.

Request a Quote Compare Products

Compliance Standards for Education

Education buildings must balance fire safety with student security and natural light. PyroSpec glass assemblies are tested to the strictest building codes across our markets.

United States

IBC Group E & NFPA 101

  • EI30 corridor walls (sprinklered)
  • EI60 exit stair enclosures
  • Combined fire + security glazing
  • ASTM E119 / UL 9 rated
  • NFPA 80 fire door assemblies
  • Storm/impact rated options
Australia

NCC 2022 Class 9b

  • AS 1530.4 fire tested
  • EI30 teaching area corridors
  • EI60 fire-isolated stairs
  • AS 4032.2 glazing compliance
  • Education Department guidelines
United Kingdom

Approved Doc B & BB 100

  • BS 476 Part 22 integrity & insulation
  • EI30 teaching block corridors
  • EI60 protected escape routes
  • DfE Building Bulletins compliance
  • Accessible glazing standards

Education Applications

School Corridor Partitions

EI30 clear glass walls separating classroom wings while enabling natural daylight penetration and teacher sightlines.

School Entrance Security Glazing

Combined fire-rated and forced-entry resistant glass for K-12 main entrances and safe haven rooms.

University Lab Viewing Windows

EI60 rated observation windows for science laboratories and lecture theatres. Clear visibility with full fire separation.

Campus Stairwell Enclosures

EI90–EI120 fire-rated glass for multi-storey campus building egress stairs. Natural light with NFPA compliance.

Frequently Asked Questions

What fire rating do K-12 school corridor walls need?

Under IBC 2021 Group E, corridor walls require EI30 in sprinklered buildings. Exit stair enclosures require EI60. Many US states also require security-level glazing at school entrances, which can be combined with fire-rated glass.

Does PyroSpec glass meet Australian school building codes?

Yes. PyroSpec assemblies are tested to AS 1530.4 and meet NCC 2022 Class 9b requirements. We supply EI30 to EI60 for school corridors and fire-isolated stairways.

Can fire-rated glass double as security glass for entry points?

Yes. PyroSpec offers combined fire-rated and impact-resistant glass for school entrances, meeting both IBC fire safety and ASTM F1233 forced-entry standards.

Planning a School or University Build?

Share your project scope, target rating and region. We will send a compliant solution within one business day.

Get a Quote